20% OFF shipping at bajadrone.com.mx on orders over $79 + up to 10% OFF products
bajadrone.com.mx
home > P6.1.4.3 Determining Planck’s Constant - Selection of Wavelengths Using Interference Filters on the Optical Bench > P6.1.4.3 Determining Planck’s Constant - Selection of Wavelengths Using Interference Filters on the Optical Bench
download picture
P6.1.4.3 Determining Planck’s Constant - Selection of Wavelengths Using Interference Filters on the Optical BenchDetermining Plancks Constant Selection of Wavelengths Using Interference Filters on the Optical Bench In the experiment P6. 1. 4. 3, the capacitor method described previously (see P6. 1. 4. 1) is used to generate the opposing voltage U between the cathode and the anode of the photocell. The voltage at the capacitor is measured without current using the electrometer amplifier. Note: The opposing voltage U can alternatively be tapped from a DC voltage
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Determining Planck’s Constant - Selection of Wavelengths Using Interference Filters on the Optical Bench

In the experiment P6.1.4.3, the capacitor method described previously (see P6.1.4.1) is used to generate the opposing voltage U between the cathode and the anode of the photocell. The voltage at the capacitor is measured without current using the electrometer amplifier.

Note: The opposing voltage U can alternatively be tapped from a DC voltage source. The I-measuring amplifier D is recommended for sensitive measurements of the anode current (see P6.1.4.4).

Components of Experiment:

1 558 77 Photocell for determining Planck's constant
1 558 791 Holder for photocell
1 460 317 Optical bench, S1 profile, 0.5 m
2 460 3112 Clamp rider with clamp 75/65
3 460 3113 Clamp rider with clamp 105/65
1 468 41 Holder for interference filters
1 468 401 Interference filter, 578 nm
1 468 402 Interference filter, 546 nm
1 468 403 Interference filter, 436 nm
1 468 406 Interference filter, 365 nm
1 460 03 Lens in frame, f=100 mm
1 460 26 Iris diaphragm
1 451 15 High pressure mercury lamp
1 451 195 Power supply unit for high-pressure mercury lamp
1 532 14 Electrometer amplifier
1 562 791 Plug-in power supply, 12 V AC
1 578 22 Capacitor, 100 pF, STE 2/19
1 579 10 Push button (NO), STE 2/19
2 590 011 Clamping plug
1 531 120 Multimeter LDanalog 20
1 501 10 BNC adapter, straight
1 501 09 BNC/4-mm plug adapter, single-pole
1 340 89 Coupling plug 4 mm
1 502 04 Distribution box with earthing socket
1 501 45 Connecting lead 19 A, 50 cm, red/blue, pair
2 500 440 Connecting lead, 19 A, 100 cm, yellow/green
1 468 404 * Interference filter, 405 nm

 


Experiment Instructions Click Here

P6.1.4.3 Determining Planck’s Constant - Selection of Wavelengths Using Interference Filters on the Optical Bench

Item no : 47452513426
sold recently : Login >>
US$ 4650.00
Pay in 4 interest-free payments of $1162.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 28 - Jul 3

Enjoy 20% off shipping

US$ 4650.00

1-11

US$ 4185.00

12-35

US$ 3255.00

36-59

US$ 2790.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches